MSDS Table of Contents Click the desired link below to jump directly to that section in the MSDS. RAYOVAC(R*) RAYOVAC CORPORATION 601 RAYOVAC DRIVE MADISON WI 53711 PHONE: 608-275-3340 FAX: 608-275-4577 HTTP://WWW.RAYOVAC.COM MATERIAL SAFETY DATA SHEET 1. WE WOULD LIKE TO INFORM OUR CUSTOMERS THAT THESE BATTERIES ARE EXEMPT ARTICLES AND ARE NOT SUBJECT TO THE 29 CFR 1910.1200 OSHA REQUIREMENT, OR TO THE CANADIAN WHMIS REQUIREMENTS AND THE SHEETS ARE SUPPLIED AS A SERVICE TO YOU. FOR OTHER MSDSS AND RELATED INFORMATION, VISIT: HTTP://WWW.RAYOVAC.COM/TECHNICAL/MSDS.HTM. 2. THESE BATTERIES CAN BE RECYCLED (SEE SECTION 7).
PRODUCT NAME: SILVER OXIDE BATTERIES SIZES: ALL EMERGENCY TELEPHONE NUMBER: 800-424-9300 (24 HR, CHEMTREC) ENVIRONMENTAL HEALTH & SAFETY INFORMATION: 608-275-2482 EDITION DATE: 03/05/2007 APPROVED BY: KEVIN J. DOMACK
INGREDIENT NAME CAS# % TLV* SILVER 7440-22-4 <0.5 .01 MG/M3 (TWA) STEEL 7439-89-6 37-41 ZINC 7440-66-6 30-40 5.0 MG/M3 (ZnO, FUME, TWA) POTASSIUM HYDROXIDE 1310-58-3 1-3 NOT LISTED GRAPHITE 7782-42-5 <0.25 15 MPPCF (TWA) MERCURY 7439-97-6 <0.9** 0.1 (MICRO)G/M3 (INORGANIC, TWA) MANGANESE DIOXIDE 1313-13-9 <2.5 C5.0 MG/M3 (Mn, TWA) WATER, PAPER, PLASTIC, BALANCE OTHER *SOURCE: OSHA 29 CFR 1910.1000 TABLE Z - 1, 2 OR 3 3-01-2007 **ALL SILVER OXIDE CELLS CONTAIN LESS THAN 25 MG/CELL OF MERCURY.
BOILING POINT @ 760 MMHg (DEG. C): NA VAPOR PRESSURE (MMHg @ 25 DEG. C): NA VAPOR DENSITY (AIR = 1): NA DENSITY (GRAMS/CC): NA PERCENT VOLATILE BY VOLUME (%): NA EVAPORATION RATE (BUTYL ACETATE = 1): NA PHYSICAL STATE: NA SOLUBILITY IN WATER (% BY WEIGHT): NA pH: NA APPEARANCE AND ODOR: GEOMETRIC SOLID OBJECT
FLASH POINT: NA FLAMMABLE LIMITS IN AIR (%): NA LOWER (LEL): NA UPPER (UEL): NA EXTINGUISHING MEDIA: USE WATER, FOAM OR DRY POWDER, AS APPROPRIATE. AUTO-IGNITION: NA SPECIAL FIRE FIGHTING PROCEDURES: AS WITH ANY FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS TO AVOID INHALATION OF HAZARDOUS DECOMPOSITION PRODUCTS (SEE SECTION 2). SPECIAL FIRE EXPLOSION HAZARDS: LIKE ANY SEALED CONTAINER, BATTERY CELLS MAY RUPTURE WHEN EXPOSED TO EXCESSIVE HEAT; THIS COULD RESULT IN THE RELEASE OF FLAMMABLE OR CORROSIVE MATERIALS.
THRESHOLD LIMIT VALUE (TLV) AND SOURCE: NA EFFECTS OF OVEREXPOSURE: NONE. (IN FIRE OR RUPTURE SITUATION SEE SECTION 2 AND SECTION 4) EMERGENCY FIRST AID PROCEDURES: SKIN AND EYES: IN THE EVENT THAT BATTERY RUPTURES, FLUSH EXPOSED SKIN WITH COPIOUS QUANTITIES OF FLOWING LUKEWARM WATER FOR A MINIMUM OF 15 MINUTES. GET IMMEDIATE MEDICAL ATTENTION FOR EYES. WASH SKIN WITH SOAP AND WATER. SWALLOWING: INGESTION OF A BATTERY CAN BE HARMFUL. CALL THE NATIONAL CAPITAL POISON CENTER (800-222-1222), DAY OR NIGHT, FOR ADVICE AND FOLLOW-UP. FOR MORE INFORMATION, VISIT: HTTP://WWW.NEMA.ORG/GOV/EHS/COMMITTEES/DRYBAT/.
STABLE OR UNSTABLE: STABLE INCOMPATIBILITY (MATERIALS TO AVOID): NA HAZARDOUS DECOMPOSITION PRODUCTS: NA DECOMPOSITION TEMPERATURE (0 DEG. F): NA HAZARDOUS POLYMERIZATION: WILL NOT OCCUR CONDITIONS TO AVOID: AVOID ELECTRICAL SHORTING.
PROCEDURES TO CONTAIN AND CLEAN UP LEAKS OR SPILLS: IN THE EVENT OF A BATTERY RUPTURE, PREVENT SKIN CONTACT AND COLLECT ALL RELEASED MATERIAL IN A PLASTIC LINED METAL CONTAINER. REPORTING PROCEDURE: REPORT ALL SPILLS IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REPORTING REQUIREMENTS. WASTE DISPOSAL METHOD: RECLAIM OR DISPOSE OF IN AN APPROVED, SECURED LANDFILL AFTER REQUIRED PRETREATMENT, PER FEDERAL, STATE AND LOCAL DISPOSAL REQUIREMENTS. FOR ADDITIONAL INFORMATION ON DISPOSAL OR RECYCLING OPTIONS, VISIT: HTTP://WWW.NEMA.ORG/GOV/EHS/COMMITTEES/DRYBAT/
RESPIRATORY PROTECTION (SPECIFY TYPE): NA VENTILATION: LOCAL EXHAUST: NA MECHANICAL (GENERAL): NA SPECIAL: NA OTHER: NA PROTECTIVE GLOVES: NA EYE PROTECTION: NA OTHER PROTECTIVE CLOTHING: NA
HANDLING AND STORAGE: STORE IN A DRY PLACE. STORING UNPACKAGED CELLS TOGETHER COULD RESULT IN CELL SHORTING AND HEAT BUILD-UP. TRANSPORTATION-SHIPPING: THESE ARE "BATTERIES, DRY" AND ARE NOT CONSIDERED TO BE A "HAZARDOUS MATERIAL" PER THE DEPT. OF TRANSPORTATION (USDOT) REGULATIONS OR "DANGEROUS GOODS" PER THE INTERNATIONAL AIR TRANSPORT ASSOCIATION (IATA) REGULATIONS. SHIPMENTS MUST COMPLY WITH THE GENERAL DUTY CLAUSE OF USDOT 49 CFR 172.102 (A) (1) SPECIAL PROVISION 130, "TO PREVENT SHORTING POTENTIAL WHILE TRANSPORTING."
NOTIFICATION IS NOT REQUIRED BECAUSE THESE PRODUCTS ARE ARTICLE(S) THAT DO NOT RELEASE A COVERED TOXIC CHEMICAL UNDER THE NORMAL CONDITIONS OF PROCESSING OR USE. NOTICE: THE INFORMATION AND RECOMMENDATIONS SET FORTH ARE MADE IN GOOD FAITH AND ARE BELIEVED TO BE ACCURATE AT THE DATE OF PREPARATION. RAYOVAC CORPORATION MAKES NO WARRANTY EXPRESSED OR IMPLIED. NA = NOT APPLICABLE |