STATE CHEMICAL MFG CO -- GREASE B GONE -- 7930-01-389-1374
===================== Product Identification ===================== Product ID:GREASE B GONE MSDS Date:02/01/1993 FSC:7930 NIIN:01-389-1374 === Responsible Party === Company Name:STATE CHEMICAL MFG CO Address:3100 HAMILTON AVE City:CLEVELAND State:OH ZIP:44114-3701 Country:US Info Phone Num:216-861-7114 Emergency Phone Num:216-861-7114 CAGE:53798 === Contractor Identification === Company Name:STATE CHEMICAL MANUFACTURING CO. Address:3100 HAMILTON AVENUE Box:City:CLEVELAND State:OH ZIP:44114-3701 Country:US Phone:216-861-7114 CAGE:53798 ============= Composition/Information on Ingredients ============= Ingred Name:A NATURAL (TERPENE-TYPE) CITRUS OIL (CONTAINING EITHER ING 2 OR 3) RTECS #:9999999ZZ Fraction by Wt: >80% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:ORANGE OIL TERPENES CAS:68917-57-7 OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:ORANGE OIL, TERPENES CAS:68647-72-3 OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:OTHER PROT EQPT: DESIGN CRITERIA RTECS #:9999999ZZ Other REC Limits:NONE RECOMMENDED ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE: MAY CAUSE EYE IRRITATION. PROLONGED SKIN CONTACT MAY CAUSE DRYNESS AND CHAPPING. CHRONIC: NO ADVERSE EFFECTS EXPECTED. Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:PRE-EXISTING SENSITIVITIES-ESPECIALLY TO CITRUS PRODUCTS ASTHMA, SINUS IRRITATIONS AND OTHER RESPIRATORY TRACT IRRITATIONS OR INFECTIONS. ======================= First Aid Measures ======================= First Aid:INGEST: CALL A PHYSICIAN OR POISON CONTROL CENTER IMMEDIATELY. INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTIFICIAL RESPIRATION) . EYES: FLUSH EYES IMMEDIATELY WITH PLENTY OF COOL WATER FOR AT LEAST 15 MINUTES. IF IRRITATION PERSISTS, CALL A PHYSICIAN. SKIN: FLUSH WITH WATER, WASH WITH SOAP AND WATER. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:>120F,>49C Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, OR FOAM Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:NONE ================== Accidental Release Measures ================== Spill Release Procedures:USE ABSORBENT MATERIAL. FLUSH RESIDUE WITH WATER. DISPOSE OF PROPERLY. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN COOL PLACE, OUT OF DIRECT SUNLIGHT. DO NOT REUSE EMPTY CNTNRS. RETURN EMPTY DRUMS TO A DRUM RECNDTNER/DESTROY BY CRUSHING. Other Precautions:READ & FOLLOW ALL LBL DIRECTIONS & PRECS BEFORE USING PROD. THESE PRODS ARE INTENDED FOR INDUS & INSTITUTIONAL USE ONLY.DO NOT STORE NEAR FOOD TO PVNT ACCIDENTAL INGEST. CAUT: COMBUST. KEEP AWAY FROM HEAT & OPEN FLAME. AVOID EYE (SUPDAT) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . Ventilation:NORMAL VENTILATION. Protective Gloves:RUBBER GLOVES ARE RECOMMENDED. Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS . Other Protective Equipment:EYEWASH STATION OR CLEAN WATER SOURCE IN CASE OF ACCIDENTAL EYE CONTACT. (MFR). EYE WASH DEVICE MEETING ANSI (ING 4) Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health % VOLAT: 100 (WT). OTHER PREC: CONT. DO NOT TAKE INTERNALLY. NOTE: BECAUSE GREASE B GONE IS POWERFUL ORG CMPD, IT MAY HARM SOME PLASTIC/PAINTED SURFS. TEST FIRST BEFORE APPLYING. SINCE THIS PROD IS EX CELLENT GREASE SOLV IT WILL EFTIVELY DEFAT SKIN. NOT FOR HOUSEHOLD USE/RESALE. KEEP OUT OF REACH OF CHILDREN. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:221F,105C Spec Gravity:0.845 Solubility in Water:EMULSIFIABLE Appearance and Odor:A CLEAR PALE YELLOW LIQUID WITH CITRUS ODOR. Percent Volatiles by Volume:SUPDAT ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES VIOLENT REACTION WITH (IF*2 + TETRAFLUOROETHYLENE) OXIDIZING MATERIALS. Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME. Hazardous Decomposition Products:NONE ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF AS AN IGNITABLE WASTE. FOLLOW ALL FEDERAL, STATE AND LOCAL REGULATIONS REGARDING WASTE DISPOSAL. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.